In situ measurements of spectral reflectance and their error sources

ORAL

Abstract

We report on progress to simultaneously measure the time-resolved spectral reflectance and radiance of materials, shock-loaded by a two-stage light gas gun. We will detail the sources of error that contribute to uncertainties and discuss the impact upon apparent surface interface temperature measurements.

*This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.