Search for Dark Photons Utilizing Advanced Germanium Detectors

ORAL

Abstract

We prospect the possibility of using advanced germanium (Ge) detectors to search for dark photons by means of absorption and conversion to electrons. A Ge detector utilizing internal charge amplification for the charge carriers created by the ionization of impurities is a novel technology with experimental sensitivity for detecting dark photons. We present the sensitivity of such a Ge experiment for detecting dark photons in the low-energy region. We show that, if Ge internal charge amplification technology becomes available, then a new opportunity arises to observe dark photons.

*This work is done under the collaboration PIRE-GEMADARC. It was sponsored by NSF OISE-1743790 and NSF OIA-1738632, DOE DESC0004768, and the state of South Dakota.

Presenters

  • Sanjay Bhattarai

    • University of South Dakota

Authors

  • Sanjay Bhattarai

    • University of South Dakota
  • Dongming Mei

    • University of South Dakota